High-rise reinforced-concrete building incorporating an oil damper in an outrigger frame and its vibration analysis

Authors

  • Yukihiro Omika Kobori Research Complex Inc., Tokyo 107-8502, Japan Author
  • Norihide Koshika Kobori Research Complex Inc., Tokyo 107-8502, Japan Author
  • Yukimasa Yamamoto Structural Engineering Group, A/E Design Division, Kajima Corporation, Tokyo 107-8502, Japan Author
  • Kenichi Kawano Structural Engineering Group, A/E Design Division, Kajima Corporation, Tokyo 107-8502, Japan Author
  • Kan Shimizu Structural Engineering Group, A/E Design Division, Kajima Corporation, Tokyo 107-8502, Japan Author

Keywords:

High-rise building, Outrigger system, Oil damper, Vibration control, Reinforced-concrete

Abstract

The reinforced-concrete multi-story shear-wall structure, which can free a building from beams and columns to allow the planning of a vast room, has increasingly been used in Japan as a high-rise reinforced-concrete structure. Since this structural system concentrates the seismic force onto multi-story shear walls inside, the bending deformation of the walls may cause excessive deformation on the upper floors during an earthquake. However, it is possible to control the bending deformation to within a certain level by setting high-strength and rigid beams (outriggers) at the top of the multi-story shear walls; these outriggers restrain the bending behavior of the walls. Moreover, it is possible to achieve high energy dissipation by placing vibration control devices on the outriggers and thus restrain the bending behavior. This paper outlines the earthquake response analysis of a high-rise residential tower to demonstrate the effectiveness of the outrigger frame incorporating vibration control devices.

Downloads

Published

2016-03-31

Issue

Section

Articles