Strength Evaluation for Cap Plate on the Node Connection in Circular Steel Tube Diagrid System

Authors

  • Seong-Hui Lee Construction Technology Exam. Division, Korean Intellectual Property Office, Daejeon, Korea Author
  • Jin-Ho Kim Research Institute of Industrial Science & Technology, Incheon, Korea Author
  • Sung-Mo Choi Department of Architectural Engineering, University of Seoul, Seoul, Korea Author

Keywords:

Diagrid, Node, Connection, Stress concentration, Cap plate

Abstract

Diagrid system has been in the spotlight for its superiority in terms of the resistance to lateral force when applied to skyscrapers. In diagrid system, most of columns can be eliminated because vertical loads (gravity loads) and horizontal loads (lateral loads) are delivered simultaneously thanks to the triangular shape of diagrid. However, lack of studies on connection shape and node connection details makes it hard to employ the system to the buildings. In this study, the structural safety of the node connections in circular steel tube diagrid system which has been considered in the Cyclone Tower in Korea (Seven stories below and fifty-one above the ground) was evaluated using the 4 full-scale specimens. The parameters are the extended length (20 mm, 40 mm & 60 mm), thickness (40 mm & 50 mm).

Downloads

Published

2012-03-31

Issue

Section

Articles