The Effect of Building Morphology on Sea Breeze Penetration over the Kanto Plain - Analysis of Mean Kinetic Energy Balance of Moving Control Volume along Sea Breeze -

Authors

  • Taiki Sato Taisei Corporation, Yokohama, 245-0051, Japan Author
  • Ryozo Ooka Institute of Industrial Science, The University of Tokyo, Tokyo, 153-8505, Japan Author
  • Shuzo Murakami Building Research Institute, Ibaraki, 305-0802, Japan Author

Keywords:

Meteorological mesoscale model, Sea breeze, Moving control volume, Mean kinetic energy balance, Heat-island phenomenon

Abstract

In order to use sea breezes to counter the heat island phenomena, i.e. to promote urban ventilation, it is necessary to clarify the effect of building morphology and height on large-scale wind fields. In this study, the sea breeze in the vicinity of the Kanto Plain in Japan is simulated using a mesoscale meteorological model incorporating an urban canopy model, and the inland penetration of sea breezes is accurately reproduced. Additionally, a mean kinetic energy balance within a domain (Control Volume; CV) moving along the sea breeze is analysed. From the results, it is clarified that the sea breeze is interrupted by the resistance and turbulence caused by buildings at the centre of Tokyo. The interruption effect is increased in accordance with the height of these buildings. On the other hand, adverse pressure gradients interrupt in the internal region.