Structural Design of Vibration Controlled Tall Buildingwith Overhang Structure

저자(들)

  • Yoji Ishibashi Structural Engineering Department, Mitsubishi Jisho Sekkei Inc., Tokyo 100-0005, Japan 저자
  • Katsuhito Yoshizawa Structural Engineering Department, Mitsubishi Jisho Sekkei Inc., Tokyo 100-0005, Japan 저자
  • Ichiro Ogawa Structural Engineering Department, Mitsubishi Jisho Sekkei Inc., Tokyo 100-0005, Japan 저자
  • Masatoshi Tamari Structural Engineering Department, Mitsubishi Jisho Sekkei Inc., Tokyo 100-0005, Japan 저자
  • Kenji Nagayama Structural Engineering Department, Mitsubishi Jisho Sekkei Inc., Tokyo 100-0005, Japan 저자
  • Hatsuka Oki Structural Engineering Department, Mitsubishi Jisho Sekkei Inc., Tokyo 100-0005, Japan 저자

키워드:

Tall buildings, Overhang, Performance-based seismic design, Damping devices, Energy absorption, Dynamic Torsional Deformation

초록

This paper describes the structural design of a 212 m tall building currently under construction in the Tokiwabashi District Redevelopment Project facing Tokyo Station. In this project there was a requirement to rationally solve many issues arising from the conditions of the redevelopment project. In particular, the following two points were considered to be important from the point of view of structural design. 1) To provide an overhang frame with the perimeter columns on the lower stories inclined, in order to enable a typical floor area that greatly exceeded the limitations of the underground structure shape. 2) To provide high grade seismic performance for the office buildings to be constructed on prime city center land. LSCVCS (Lower Stories Concentrated Vibration Control System) was proposed as the method of rationally designing the overhang frame, which is an extremely disadvantageous element in the structural scheme of the tall building with a large slenderness ratio. LSCVCS is a system to provide effective damping by arranging vibration control devices in a concentrated manner in a lower story with large story height, that produces large deformation in an earthquake. Also, the vibration control devices arranged in the lower story are limited to viscous devices, to take into consideration the residual deformation of the overhang frame after an earthquake. The results of investigations into the specific effects of the system for the seismic design are reported, including Performance-based seismic design.

다운로드

출판됨

2019-09-30

권호

세션

Articles